The IT - 5405 Weight Controller is a
very accurate and versatile weight
indicator which is used for a wide
variety of process weighing
applications including filling or
dispensing liquid. Whether Filling
or dispensing solids or liquids, the
IT - 5405 Weight Controller
automates the entire process. Its
variety of interface options and
selectable specific scale functions
perfectly fit to weighing systems
and process control systems.
IT-5405 increases the flexibility by
offering the possibility to
implement specific functions /
interlocking with its free
programmable feature.
The instrument is approved by
Weights & Measures Authorities for
use in Accuracy class II & III.
Large 6 digit LED weight display
(red) with weight status information
and tactile 6 key keyboard for basic
scale functions and numeric data
entry
Specification
|
ACCURACY |
|
Accuracy
class |
Class III |
|
|
|
DISPLAY AND KEYBOARD |
|
Display |
6 digits, 7
segments, LED red |
|
Status
annuciators |
Gross, Net,
Motion, Zero, Weighing
ranges, Information, Unit |
|
Keypad |
4 - Key
membrane, with tactile
feedback |
|
Decimal
point |
between any
digit of the display |
|
|
|
TERMINAL FEATURES |
|
Record
Capacity |
more than
4500 weighing records |
|
Application
Software |
Truck scale
software or labelling
software |
|
|
|
|
A/D
CONVERTER |
|
Type |
|
|
Conversion
Rate |
|
|
Analogue
Input Range |
0mV to 20mV |
|
Resolution |
display upto
60000 counts |
|
|
|
SCALE
CALIBRATION AND FUNCTIONS |
|
Calibration |
calibration
is performed by application
standard weights |
|
Corner
adjustment |
only
externally |
|
Weighing
Functions |
Tare, Zero,
Auto Zero Tracking, Motion
detection, Auto-Zero at
power up |
|
|
|
LOAD
CELLS |
|
Communication & Protocol |
for Analog
Load cell |
for Digital
load cells |
|
Excitation |
5 V DC |
12V Dc |
|
Number of
Load cells |
Upto 10 Load
cells or
18 Loadcells in parallel |
Upto 10
Digital Load cell |
|
connection |
4 or 6 wire
technique |
4 wire
technique |
|
|
|
COMMUNICATION |
|
Serial
Interface |
RS 232C for
second scale connection,
data transfer or serial
printer connection |
|
parallel
Port |
parallel
data interface for printer
connection |
|
|
|
ENVIRONMENT AND ENCLOSURE |
|
Operating
Temperature |
Temperature
-10°C to +40°C Temperature
|
|
Housing |
panel type
(front panel) or stainless
steel housing |
|
|
|
OPTION FOR ADDITIONAL
INPUTS/OUTPUTS (maximum is
one option per instrument) |
|
2nd Serial
Interface |
RS232C for
remote display |
|
2nd or 3rd
Serial Interface |
Interface 2
is RS232c, Interface 3 is
RS232c or RS485 can be used
for RTU Modbus |
|
Ethernet
TCP/IP |
Data
transfer via Ethernet
interface |
|
|
|
ADDITIONAL MECHANICAL
HARDWARE |
|
Wall mount
kit |
|
Stand Mount
Kit |
|